Skip to content

YANTON DR-9000

Características

GENERAL

ParámetroEspecificación
Frequency136–174 MHz / 400–480 MHz
RF Output25 W
Channels Capacity16
Weight14.5 kg
Digital ProtocolETSI-TS102 361-1, -2, -3
Operating Voltage13.6 V DC ±20%
AC PowerAC 100–250 V, 50/60 Hz
Operating Temperature-20 °C ~ +60 °C
Dimension483 × 309 × 133 cm*

TRANSMITTER

ParámetroEspecificación
Channel Space12.5 kHz / 25 kHz
Intermodulation±2.5 kHz @ 12.5 kHz / ±5.0 kHz @ 25 kHz
Hum and Noise-40 dB @ 12.5 kHz / -45 dB @ 25 kHz
Spurious Response-36 dB < 1 GHz / -30 dBm > 1 GHz
Adjacent Channel Selectivity-60 dB @ 12.5 kHz / -70 dB @ 25 kHz
Audio Distortion≤3%
Digital Sensitivity12.5 kHz 7k60FXD / 12.5 kHz 7k60FXE

RECEIVER

ParámetroEspecificación
Frequency Stability-20 °C +60 °C +25 °C ±0.5 PPM*
Analog Sensitivity0.3 μV (12 dB SINAD)
Analog Sensitivity — Type0.22 μV / -120 dBm (Type)
Digital Sensitivity0.22 μV / -120 dBm
Digital Sensitivity0.35 μV / -116 dBm
Adjacent Channel Selectivity60 dB @ 12.5 kHz / 70 dB @ 25 kHz
Audio Distortion≤3%
Spurious Response-57 dBm < 1 GHz / -47 dBm > 1 GHz